Taryn Rose

Digital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+Interpretation

Description: Upper Arm Blood Pressure Monitor 24h BP Recorder+Software+Finger Pulse Oximeter Digital ECG/EKG Machine 12-lead Electrocardiograph CONTEC Description ECG90A with PC software/InterpretationIntroductionECG90A is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in: recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for "Lead off" or "Lack of paper", optional interface languages(Chinese/English), case database management.Function1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Particular and high-accurate digital filter eliminates baseline drift, no distortion to ECG waveform, greatly enhances anti-baseline drift capacity, convenient for waveform judgment.3)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.4)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).5)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz. 6)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.7)Optional SD card stores up to 100 cases, which is convenient for doctor to review case and statistic.8)In review mode, case waveform stored can be checked, measurement parameter and diagnosis information can be automatically analyzed.9)Two languages(Chinese or English) interface and report.10)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, collect real-time data to the software for analyzing and printing the report, and old cases stored in Electrocardiograph can be uploaded to PC.11)Power supply: AC/DC, and in optimal DC state, built-in rechargeable lithium battery can continuously work for 4-hour, print up to 90-minute and 150-ECG, which meets the requirements of visiting a patient at home and body examination. Rechargeable lithium battery is detachable, which is convenient for user to replace and charge in any time.PerformanceInput mode: floating and defibrillation protectionFrequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)CMRR: >60dB, >100dB(add filter)Time constant:≥ 3.2sPatient leak current: <10µACalibration voltage: 1mVSensitivity: 5, 10, 20 mm/mV ±5%, standard sensitivity: 10mm/mV±2%Noise level: ≤15µVp-pInput circuit current: ≤50nAInput impedance: ≥50MΩSampling accuracy: 12-bitSafety classification: class I, type CF and defibrillation-proof applied partRecording mode: thermal printing systemMeasurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)Paper size: 50mm(W)×20m(L)Sampling frequency: 1000HzPolarizing voltage: ±500mVEMG interference filter: 25Hz/35Hz (-3dB)Power frequency filter: AC 50Hz/60Hz(-20dB)Paper speed: Auto: 6.25, 12.5, 25, 50mm/s, ±5%Manual: 6.25, 12.5, 25, 50mm/s, ±5%ECG300G 3 Channel / ECG600G(Touch) 6-Channel / ECG1200G(Touch) 12 Channel with PC Software and Automatic Interpretation CE FDAIntroductionIt is an Electrocardiograph which can collect 12-lead ECG signal simultaneously and print waveform by thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, optional rhythm lead that convenient to observe abnormal heart rhythm, case database management, etc.Function1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.3)Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, auto 3-2+1, auto 3-2, auto 1x12+1, auto 1x12, rhythm 4, rhythm 3, rhythm 2, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements.4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.5)Build-in large capacity memory stores at least to 1000 cases, which is convenient for doctor to review case and statistic.6)Multi- language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Russian, Ukrainian, Serbian, Vietnamese, Slovenian, Slovak, Bulgarian and Nigerian language) interface and report.E3/E3M 3 Channel/ E6(touch)6 Channel/ E12(Touch)12 Channel with PC software&Auto InterpretationIntroductionIt is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rhythm; case database management, etc. Accessories Function1) External printer and USB storage device can be connected.2) Sync collection for 12-lead ECG, support routine 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via AC filter, DFT filter, EMG filter and Low-pass Filter of ECG signal.3) Display 3/6/12 - lead ECG waveform, print mode, sensitivity, paper speed, filter status, etc. on one screen, convenient for contrastively diagnosing.4) Power supply: AC/DC (which can adapt AC 50/60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.5) Support for auto 1*12, auto 2*6, auto 2*6+1, auto 3*4, auto 3*4+1, auto 4*3, auto 4*3+1, auto 6*2, auto 6*2+1, rhythm 7, rhythm 6, rhythm 5, rhythm 4, rhythm 3, rhythm 2 and manual. The printed content contains time, calibration signal, filter status and patient’s information. Information including printed waveform length, output measurement parameters, diagnostic conclusion, superposition QRS wave, histogram, trend chart, interval list, can be set, and with time print function, which meets different requirements.6) With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measurement results for HR, PR interval, P Duration, QRS Duration, T Duration, QT/QTc interval, P/QRS/T Axis, R(V5), S(V1) and R(V5)+S(V1), etc. and auto-diagnosis conclusion, which reduces the doctor’s burden.7) Rhythm lead can be selected freely, convenient to observe abnormal heart rhythm.8) The subject’s clinical information (such as, ID, Name, Age, Sex, Height, Weight, etc.) can be entered.9) 1000 cases (3 s case is frequently used) can be stored by the built-in memory, convenient for case review and statistic.10) In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour and print up to 1000 ECG waveform (3 s case is frequently used).11) Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report.ECG1201G Full Keyboard IntroductionThe device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for “Lead off” and “Lack of paper”; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.Functions1)Adopt 7'' high-resolution color LCD, operate by buttons, convenient to use.2)Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 / 60 Hz), baseline filter and EMG filter (25 / 35 Hz) of ECG signal.3)Display 1 / 3 / 6 / 12 - lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, battery power, background grid, etc. on one screen, and with prompt functions for lead - off, overload and system working state.4)Power supply: AC / DC (which can adapt AC 50 / 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.5)In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.6)Built-in thermal printer, support multiple printing modes, such as, auto M × N, M × N + 1, M × N + 2, rhythm M line and manual, etc. The contents including time, paper speed, sensitivity, calibration signal, lead name, filter state and patient information can be printed. The waveform length printed, measurement parameter output, diagnosis conclusion, superimposed QRS waveform, histogram, trend chart and interval list, etc. can be set. With the timing print functions, which meet different requirements.7)With the functions of auto-measurement and auto-interpretation for routine ECG parameters, provide measured results and auto-diagnosis conclusions for HR, PR interval, P Duration, QRS Duration, QT / QTc interval, P / QRS / T Axis, R (V5), S (V1), R (V5) + S (V1) amplitude, etc. which reduces the doctor’s burden.8)Historical cases can be reviewed, inquired, modified, transmitted, printed, lead corrected, the cases can also be exported to other electronic file formats (dat, xml, bmp, png)9)Multi-language (Chinese, English, Turkish, Portuguese, German, Russian and Kazakh, etc.) interface and report.10)Support external USB standard keyboard, scanner and printer.Performance1)Input mode: floating and defibrillation protection2)Lead: standard 12-lead3)Patient leak current: < 10 µA4)Input impedance: ≥ 2.5 MΩ5)Frequency response: 0.01Hz-300Hz (-3dB)6)Time constant: ≥ 3.2 s7)CMRR: > 105 dB8)Filter: power frequency (AC 50 / 60 Hz), EMG (25 Hz / 35 Hz (-3 dB)) and baseline drift9)Recording mode: thermal printing system10)Paper size: 210 mm (W) × 20 m (L), high-speed thermal paper11)Paper speed:5 mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 %12)Gain (sensitivity): 2.5,5, 10, 20 ,40mm / mV, accuracy: ± 2 %Standard sensitivity: 10 mm/mV ± 0.2 mm/mV13)Record mode: auto, rhythm and manual record14)Measurement parameters: HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude15)Safety class: class I, defibrillation-proof type CF applied part16)Polarizing voltage: ± 610 mV17)Noise level: ≤ 12 µVp-p18)Sampling frequency for ECG signal input: 32 kHz19)Sampling frequency for waveform data processing: 1 kHz20)Sampling accuracy: 24 - bit21)Minimum detection signal: a 10 Hz, 20 µV (peak - peak value) sinusoidal signal can yield a visual recorded deflection.22)Pacemaker detection channel: all leads23)Accuracy of input signal reproduction: ± 5 %24)Amplitude quantization: ≤ 5µV/LSB25)Time deviation in each channel: <100 µs26)Power supply: AC: 100V ~ 240V (50 / 60 Hz)DC: 14.8 V / 5200 mAh rechargeable lithium battery27)Degree of protection against ingress of liquid: IPX028)Working mode: continuous operationECG100G single channel 12-lead without Software,NO interpretationIntroductionECG100G is a kind of single channel electrocardiograph, which features in printing ECG waveform by thermal printing system, prompting for "Lead off" or "Lack of paper", multi-language interface, recording ECG waveform in AUTO/Manual mode, convenient to operate.Function1)Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.2)Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.3)Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).4)In AUTO mode, finish recording by pressing the button once, which improves work efficiency.5)Multi-language (Chinese, English, French, Italian, German, Spanish and Turkish) interface and report.6)In optimal DC state, up to 7-hour standby time, continuous print up to 4-hour, record up to 150 ECG waveform. Shipping International Buyers - Please Note: * Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.* Please check with your country customs office to determine what additional costs will be prior to bidding Terms of Sale Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved Only English User manual,Please contact us if you need other language version.

Price: 229 USD

Location: Qinhuangdao,Hebei

End Time: 2024-01-29T03:57:29.000Z

Shipping Cost: 0 USD

Product Images

Digital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+InterpretationDigital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+InterpretationDigital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+InterpretationDigital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+InterpretationDigital ECG EKG Machine 12 Lead 3/6/12 Channel Electrocardiograph+Interpretation

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 60 Days

Refund will be given as: Money Back

Brand: CONTEC

Mounting: Cart Mounted

Number of Leads: 12

Number of Channels: 3

ECG & EKG Machine Type: Electrocardiograph

Features: Printer

MPN: 69450401

Operation: Digital

Country/Region of Manufacture: China

Application: Resting

Available Variations

Color: ECG300G

Price: 459 USD

Available Quantity: 50

Quantity Sold: 0

Color: E3M

Price: 459 USD

Available Quantity: 50

Quantity Sold: 0

Color: E3

Price: 519 USD

Available Quantity: 50

Quantity Sold: 0

Color: ECG600G

Price: 559 USD

Available Quantity: 50

Quantity Sold: 0

Color: E6

Price: 599 USD

Available Quantity: 50

Quantity Sold: 0

Color: ECG1200G

Price: 699 USD

Available Quantity: 50

Quantity Sold: 0

Color: ECG1201G

Price: 899 USD

Available Quantity: 50

Quantity Sold: 0

Color: E12

Price: 799 USD

Available Quantity: 50

Quantity Sold: 0

Color: ECG90A

Price: 299 USD

Available Quantity: 50

Quantity Sold: 0

Color: ECG100G No interpretation

Price: 229 USD

Available Quantity: 50

Quantity Sold: 0

Recommended

CONTEC Touch Digital 12 channel ECG/EKG Machine Electrocardiograph PC Software
CONTEC Touch Digital 12 channel ECG/EKG Machine Electrocardiograph PC Software

$269.00

View Details
CONTEC SC21 Stethoscope Professional Cardiology Doctor Nurse Medical Healthcare
CONTEC SC21 Stethoscope Professional Cardiology Doctor Nurse Medical Healthcare

$7.99

View Details
CMS50D-bt  SPo2 Fingertip Blood Oxygen Pulse Oximeter +USB +Software FDA CONTEC
CMS50D-bt SPo2 Fingertip Blood Oxygen Pulse Oximeter +USB +Software FDA CONTEC

$36.00

View Details
New NIBP Cuff pediatric/Adult for Contec Patient Monitor/Blood Pressure Monitor
New NIBP Cuff pediatric/Adult for Contec Patient Monitor/Blood Pressure Monitor

$10.45

View Details
CONTEC CB100 Ambulatory Multi-parameter Recorder 24h NIBP Spo2 ECG+PC Software
CONTEC CB100 Ambulatory Multi-parameter Recorder 24h NIBP Spo2 ECG+PC Software

$650.00

View Details
US ship CONTEC Ambulatory Blood Pressure Monitor+Software 24h NIBP Holter ABPM50
US ship CONTEC Ambulatory Blood Pressure Monitor+Software 24h NIBP Holter ABPM50

$149.00

View Details
Portable Laptop Machine Digital Ultrasound Scanner 4 Probes Optional,CE FDA New
Portable Laptop Machine Digital Ultrasound Scanner 4 Probes Optional,CE FDA New

$1249.00

View Details
NIBP Cuff For CONTEC Blood Pressure Monitor&Patient Monitors,Reusable
NIBP Cuff For CONTEC Blood Pressure Monitor&Patient Monitors,Reusable

$26.39

View Details
CONTEC ABPM50 Arm 24h NIBP Ambulatory Blood Pressure Monitor+PC Software+3 cuffs
CONTEC ABPM50 Arm 24h NIBP Ambulatory Blood Pressure Monitor+PC Software+3 cuffs

$179.00

View Details
Contec TLC5007 Dynamic ECG System
Contec TLC5007 Dynamic ECG System

$155.00

View Details