Taryn Rose

Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe

Description: CMS60D1 Pulse Oximeter with 3 probes Adult+Child+Neonate, Handheld Rechargeable +PC Software Brief introduction 1 Introduction Introduction CMS60D1 Pulse Oximeter adopts Photoelectric Oxyhemoglobin Inspection Technology integrated with Capacity Pulse Scanning & Recording Technology, which can be used to measure human oxygen saturation and pulse rate through finger. The device is suitable for use in family, hospital, oxygen bar, community healthcare and physical care in sports, etc. (It can be used before or after exercise, but not recommended to use during exercising). Features 1.Display of SpO2 value 2.Display of pulse rate value and bar graph 3.Display of pulse waveform 4.Display of PI value(selection function) 5.Chinese and English bilingual switch 6.With function menu 7.Clock function 8.Review function 9.Code lock protection alarm function 10.Alarm function(Finger out or out of limit) 11.Battery power indication, Ultra low power warning function 12.Adjustable screen brightness 13.Adjustable sound volume 14.Restore factory Settings 15.Storage function for SpO2 and PR values, and data stored can be uploaded to PC 16.Real-time data can be uploaded to PC 17.Bluetooth connection to PC(optional) 18.External SpO2 probe can be connected Performance Display mode:2.8'' color screen Screen resolution: 240* 320 SpO2 measurement range: 0 % ~ 100 %(resolution: 1 %) Accuracy: 70%~100%: ±2% 0%~69%: unspecified PR measurement range: 30 bpm~250 bpm(resolution: 1 bpm) Accuracy: ±2 bpm during the pulse rate range of 30 bpm ~ 99 bpm and ±2% during the pulse rate range of 100 bpm ~ 250 bpm. PI(selection function) measurement range: 0 % ~ 20 % Accuracy: 1% ~ 20 %, allowable absolute error: ± 1 %; 0 % ~ 0.9 %, allowable absolute error: ± 0.2 % Accuracy under low perfusion: low perfusion 0.4 %, SpO2 accuracy: ± 4 %; PR accuracy: ±2 bpm during the pulse rate range of 30 bpm ~ 99 bpm and ±2% during the pulse rate range of 100 bpm ~ 250 bpm. Light interference: compared to the values measured in normal condition and ambient light condition, the deviation: ≤ ± 1 %. Power consumption: ≤ 0.84V·A Working voltage: DC3.3V ~ 4.2V Battery: A rechargeable built-in lithium battery, after the power failure of the equipment, the battery can continue to work. Battery life:Charging and discharging not less than 500 times Safety class: ClassⅡ, type BF applied part Physical characteristic Dimension: 159 mm(L) × 72 mm(W) × 31 mm(H) Weight: about 250 g(including battery) Buy safe products The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item. The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The Fingertip Pulse Oximeter that is FDA 510K Approved International Buyer--Please note: Import duties,Taxes are not included in the item price.These charges are buyers' responsibility We are the manufacturer of medical equipment for 17 years, the following are our main products: ECG / ECG holter EEG / EEG Holter B-ultrasound Patient Monitor Fetal doppler Fetal Monitor Spo2 Monitor Stethoscope Medical Image.... Agent in the world! We are look for partners in the world now! Do you want to become our agent in you conutry? Join US! Skype:xuebox3 contec.med.mary at hotmail.com Only English User Manual,Please contact us if you need other language version.thank youThis product is sold worldwide, if you are using it in the United States, please contact me before purchasing

Price: 149 USD

Location: QinHuangDao HeBei

End Time: 2024-11-21T08:26:35.000Z

Shipping Cost: 0 USD

Product Images

Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe Fingertip Pulse Oximeter Pediatric SpO2 Monitor,Adult+child+neonatal probe

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 60 Days

Refund will be given as: Money Back

Brand: CONTEC

MPN: Does Not Apply

Form Factor: Handheld

Oximeter Type: Pulse Oximeter with Probe, Array

Intended Use/Discipline: Family Medicine, Array

Model: CMS60D1+3probes

Country/Region of Manufacture: China

Type: oximeter

Recommended

Finger Pulse Oximeter Test SpO2 Sensor Heart Rate Meter Blood Oxygen O2 Monitor
Finger Pulse Oximeter Test SpO2 Sensor Heart Rate Meter Blood Oxygen O2 Monitor

$8.99

View Details
CONTEC Neonatal Infant Child Pulse Oximeter 24H SPO2 PR Monitor PC Software,USA
CONTEC Neonatal Infant Child Pulse Oximeter 24H SPO2 PR Monitor PC Software,USA

$99.00

View Details
Finger Tip Pulse Oximeter Blood Oxygen meter SpO2 Heart Rate Monitor Saturation
Finger Tip Pulse Oximeter Blood Oxygen meter SpO2 Heart Rate Monitor Saturation

$9.99

View Details
Contec TLC5007 Dynamic ECG System
Contec TLC5007 Dynamic ECG System

$180.09

View Details
CONTEC SC12 Multi-functional Stethoscope Single Tube Doctors Nurse Cardiology
CONTEC SC12 Multi-functional Stethoscope Single Tube Doctors Nurse Cardiology

$9.99

View Details
FDA CONTEC08A Digital Arm Blood Pressure Monitor Infant Child Adult 4 NIBP Cuffs
FDA CONTEC08A Digital Arm Blood Pressure Monitor Infant Child Adult 4 NIBP Cuffs

$69.99

View Details
CONTEC Adult SpO2 Probe For Patient Monitor,Pulse Oximeter Reusable Sensor 8000
CONTEC Adult SpO2 Probe For Patient Monitor,Pulse Oximeter Reusable Sensor 8000

$23.39

View Details
CMS50D-bt  SPo2 Fingertip Blood Oxygen Pulse Oximeter +USB +Software FDA CONTEC
CMS50D-bt SPo2 Fingertip Blood Oxygen Pulse Oximeter +USB +Software FDA CONTEC

$36.00

View Details
ECG/EKG Machine Digital One Channel 12 lead Electrocardiograph CONTEC ECG100G CE
ECG/EKG Machine Digital One Channel 12 lead Electrocardiograph CONTEC ECG100G CE

$269.00

View Details
New NIBP CUFFS pediatric/Adult for CONTEC Patient Monitor/Blood Pressure Monitor
New NIBP CUFFS pediatric/Adult for CONTEC Patient Monitor/Blood Pressure Monitor

$10.80

View Details