Description: Rated supply voltage100 to 240 VAC (50/60 Hz)Operating voltage range85 to 110% of rated supply voltagePower consumptionApprox. 6.2 VATime ranges(Number of ranges)10Time ranges0.001 to 9.999 s 0.01 to 99.99 s 0.1 to 999.9 s 1 to 9999 s 0.1 to 999.9 min 1 to 9999 min 0.1 to 999.9 h 1 to 9999 h 1 s to 99 min 59 s 1 min to 99 h 59 minInput methodNo-voltage (NPN)/Voltage (PNP) input (selectable)No-voltage inputSolid state inputShort-circuit (ON) impedance: 1 kΩ max. (Leakage current (0 Ω): Approx. 12 mA) Short-circuit (ON) residual voltage: 3 V max. Open circuit impedance: 100 kΩ min. (The DC voltage must be 30 VDC max.)Contact inputUse contact which can adequately switch 5 mA at 10 VApplicable two-wire sensorLeakage current: 1.5 mA max. Switching capacities: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDCVoltage inputHigh level: 4.5 to 30 VDC Low level: 0 to 2 VDC (Input resistance 4.7 kΩ)Output modesA: Signal ON delay (Ⅰ) A-1:Signal ON delay (Ⅱ) A-2: Power ON delay (Ⅰ) A-3: Power ON delay (Ⅱ) b: Repeat cycle (Ⅰ) b-1: Repeat cycle (Ⅱ) d: Signal OFF delay E: Interval F: Cumulative Z: ON/OFF-duty adjustable flicker S: Stopwatch toff: Flicker OFF start (Ⅰ) ton: Flicker ON start (Ⅰ) toff-1: Flicker OFF start (Ⅱ) ton-1: Flicker ON start (Ⅱ)Control output (Contact output)Time-limit contact: SPDT Resistive load: 5 A at 250 VAC/30 VDC (cosφ = 1) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)Reset systemPower reset (depending on output mode)/Automatic reset (depending on output mode)/External reset/Manual resetPower resetMinimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode)Timer modeElapsed time (UP) and remaining time (DOWN) (selectable)Display method7-segment negative transmissive LCD 4 digitCharacter heightPresent value: 12 mm (Red, green or orange programmable) Set value: 6 mm (green)Key protect methodKey protect SwitchMemory backup methodEEP-ROM (number of writes: 100,000 operations min., Service life: 10 years min.)Ambient temperature (Operating)-10 to 55 ℃ (with no freezing or condensation) When mount timer side by side: -10 to 50 ℃ (with no freezing or condensation)Ambient temperature (Storage)-25 to 70 ℃ (with no freezing or condensation)Ambient humidity (Operating)25 to 85>#/td###Accuracy of operating timePower-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)Setting errorPower-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)Influence of voltagePower-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)Influence of temperaturePower-ON start: ±0.01% ±0.05 s max. (The values are based on the set value.) Signal start: ±0.005% ±0.03 s max. (The values are based on the set value.)Insulation resistanceBetween current carrying terminals and exposed non-current carrying metal parts: 100 MΩ min. (at 500 VDC) Between non-continuous contacts: 100 MΩ min. (at 500 VDC)Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between operating power circuit and input circuit: 2000 VAC 50/60 Hz 1 min Between control output, and power supply/input circuit: 2000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1000 VAC 50/60 Hz 1 minImpulse withstand voltageBetween power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kVNoise immunityBetween power terminals: ±1.5 kV Between input terminals: ±600 kV square-wave noise by noise simulator, pulse width: 100 ns/1 µs, 1-ns riseStatic immunityMulfunction: 8 kV, Destruction: 15 kVVibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz 0.35 mm single amplitude each in 3 directions for 10 minShock resistanceDestruction: 300 m/s2, 3 times each in 3 axes each directions Malfunction: 100 m/s2, 3 times each in 6 directionsLife expectancyElectrical: 100,000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h, 23 ℃) Mechanical: 10 million operations min. (under no load at 1,800 operations/h, 23 ℃)Degree of protectionIEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter)Mounting methodFlush mountingExternal connection methodScrew terminalCase colorBlack (Munsell N1.5)AttachmentFlush mounting adapter, waterproof packing, label for DIP switch settings, terminal coversAccessory (sold separately)Soft Cover: Y92A-48F1 Hard Cover: Y92A-48 Flush mounting adapter: Y92F-30/Y92F-45/Y92F-38 Waterproof packing: Y92S-29 Replacement Front Panel: Y92P-CXT4S/Y92P-CXT4G/Y92P-CXT4BWeightMain Unit: Approx. 115 g As of February 24, 2021
Price: 187 USD
Location: Miami, Florida
End Time: 2024-01-01T05:10:46.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Custom Bundle: No
Modified Item: No
MPN: H5CXAN
Controller Platform: Automate
Brand: Omron
Type: Timer Relay