Description: Feature:1. MULTIPLE MODES: This is a special control module for stepping, servo motor. This module has no programmable function, but built in a variety of fixed mode, the user can quickly choose the appropriate trajectory 2. CONFIGURABLE AND PRACTICAL: Stepper motor motion controller support power down save and set distance, speed, delay, cycle times 3. VARIOUS WAYS OF USE: Can be independently run as a module, can also cooperate with other systems, as a third party module to make up for the lack of motor output shaft 4. APPLICATION SCENARIO: Widely used in industrial automation control, small mechanical equipment, automatic painting industry, indexing tool control industry 5. EXCELLENT PERFORMANCE: Made with fine workmanship, possess compact appearance and stable performance, can make sure durability and stability Specification: Item Type: Stepper Motor Motion Controller Case Size(LxWxH): Approx. 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in Screen Structure: 5 digit, high light digital tube Operating Environment: -5℃-60℃ (no condensation) Opening Size(LxW): Approx. 92 x 69.8mm / 3.62 x 2.75in Motor Pulse Frequency: 85K HZ Input: Enter 7. The input takes 0V as the valid signal [F] Function Summary: In the actual work, the parameters (internal parameters of the system) that do not need to be modified often are focused on this. Serial NumberFunction(with * is not recommended to adjust)RangeDefault valueF1Molecular (electronic gear ratio) (see below for details on the specific algorithm)0-655358F2Denominator (electronic gear ratio) (see below for details on the specific algorithm)0-655355F3* Minimum speed (the minimum speed limit at which the motor is allowed to operate) Unit: Class0-655350F4* Maximum speed (the maximum speed limit at which the motor is allowed to operate) Unit: Grade0-17811781F5Zero finding position (useful only when mechanical zero) Unit: based on gear ratio0-65535.9991.5F6Zero finding speed (useful only when machine is zero) Unit: level0-6553550F7Zero seeking mode (0: software zero 1-3: mechanical zero, where 1 is recommended, do not use 2)0-30F8* Zero function start point (useful only when the machine is zero) Unit: the gear ratio shall prevail0-65535.99965535F9* Acceleration (the acceleration level of the motor starting to the normal speed, the larger the faster) the acceleration and deceleration values should be consistent as far as possible0-65535 level2000F10* Deceleration (deceleration level from normal motor speed to stop, the larger the faster) acceleration and deceleration values should be consistent as far as possible0-65535 level2000F11* System internal debugging parameters, do not set0-2553F12* System internal debugging parameters, do not set0-42949672956400Function 13*X0-X1-X2 Input signal filtering time unit: level0-6553540When there is external interference, set again. The larger the value, the slower the responseF14The magnitude of THE SPEED CHANGE in (can be turned off in F16) Unit: Level0-2552When the motor is in , the current running speed can be modified through the knob (encoder) on the panel. The magnitude of the knob change speed is determined by this parameter. The greater the value, the knob, the greater the range of speed! The smaller the better.Note: The speed after speed change is not saved by default after power failure. If you want to save after power failure, press the "Confirm" button to save in standby state. "Speed-saue" is displayed.F15Is it automatically returned to zero after startup? (0: does not return to zero upon startup 1: automatically returns to zero upon startup)0-10Note: If automatic return to zero is set on startup, software zero is used for return to zero by default. The mode needs to be set in [F5-F8] function. If mechanical zero is set, it is recommended to set the zero back to mechanical zero F7=1 for the best effect! Returning to zero can only be a reversal!F16* Special function Settings0-2550Value 0- Normal does not enable any special functions (default)Value 1- Forces knob speed change to turn off.Value 2- Modifies the motor rotation direction.Value 4- Enables RS485 communication (following RTU protocol). The agreement specification can be downloaded from the official website.Value 8- Automatically runs the job when turned on. The controller can be externally connected to the start button, direct wire to start port and 0V short circuit, can also play a similar effect.Value 16- Running knob speed regulation, whether the forward and reverse change simultaneously. You are not advised to use this function. Note: IF you want to change the speed at the same time, the forward and reverse running speed values should be the same. The P2 = P4. ifIf not, the speed will be unexpected.For example:1: If you want to modify the motor rotation direction, refer to the above value of 2. So F16 is equal to 2, which means change direction2: Now to open the RS485 communication function (value :4), and to change the motor rotation direction (value :2). F16=4+2=6F17* Selective switch P interface or F interface 1- off [P] on [F] 2- on [P] off [F] 3- All off (temporary open: press the [Setting] key before starting up)0-30F18* The higher the multiple PSC value of motor running speed, the slower the speed1-655353The purpose is to adapt to some special occasion. If the motor is required to work at a very slow speed (only one turn a day, etc.).F19* Multiple of acceleration and deceleration (used in special cases, generally not set)1-2551On some occasion, express acceleration and deceleration are required. In this case, a large value of acceleration and deceleration is needed (the higher the value, the faster the deceleration). By default, the value F9: acceleration or F10: deceleration will not be large enough. In order to increase the number of acceleration and deceleration, so the multiple appears.The final acceleration and deceleration value = (F9: acceleration or F10: deceleration value) X (F19 value)F20The main screen displays contents0-600- Absolute position (positive and negative coordinates can be displayed) where "-" indicates reversal. Unit: circle or distance value or Angle. The display significance of the value is completely determined by the value of [F1] and [F2]. Calculate the value of [F1] [F2] in advance and it will display correctly1- Absolute position (only positive coordinates can be displayed). Calculate the value of [F1] [F2] in advance and it will display correctly.2- Relative position. That is, the current value of the motor is displayed (positive and negative coordinates can be displayed). If "-" is displayed, the switch is reversed.3- Output pulse frequency (unit :KHZ) Maximum error: ±1KHZ, theoretical maximum frequency: 85Khz4- Motor lap time (unit: RPM, maximum error ±90 RPM. Please fill in the real drive sub-score in [F1, otherwise the display is incorrect])5- Motor travel distance speed (unit: mm/ SEC, maximum error ±2mm/ SEC. The value of [F1] [F2] should be calculated in advance, otherwise the display is incorrect)6- Actual speed value of the controller (i.e. [P2] [P4]) unit: level7- The value of the forward transfer delay (that is, the value of [P6]) in seconds8- The value of the inversion in place delay (i.e., the value of [P7]) in seconds9- Working times display (power off not saved) Unit: times. Maximum 99999. After that, "-----" is displayedF21* Press the Return ESC(emergency stop) key0-300- The motor will stop slowly according to the deceleration speed (if it is in the state of acceleration and deceleration, it will stop immediately) 1- The motor will stop immediately (impact)2- The motor stops slowly and automatically returns to zero according to the reduced speed. Press again to pause back to zero. Press it again, it goes back to zero, and the cycle continues3- The motor stops slowly according to the deceleration speed, and the coordinate is cleared to zero (the motor does not move)F22* Button (including start/emergency stop) signal filtering time Unit: level0-6553520When there is external interference, set again. The larger the value, the slower the responseF23* Allow to change the value of P0 0- Allow to enter Modify >0 Do not allow to change0-655350In practical work, the user will often modify the parameters of P1-P8, while the parameter P0 is used to select the corresponding action trajectory. Generally, after setting, it will not be changed often. So I can lock it up here to prevent accidental changes.After the switch is locked, the screen blinks: ERR-0 when you change the parameters of P0In F17, you can selectively hide the function menu P interface or F interface.Combining the above: we can set F17 to 2 and F23 to 1. In this way, users are only allowed to modify commonly used parameters. Some system key parameters, the user is not touch, so as to play a protective role.F24Note: After changing this parameter, power off and restart is required for it to take effect0-4 or >1041- Only [F] parameter is restored. 2- Only [P] parameter is restored3- Restore all (recommended) 4- No restore required0 or >10: Restore all and enable self-test mode, manufacturer mode (only for manufacturers, users do not set this parameter)
Price: 31.33 USD
Location: Shenzhen
End Time: 2024-10-04T13:59:23.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Return policy details:
Manufacturer Part Number: Does Not Apply
MPN: Does not apply
Brand: Unbranded
Type: Stepper Motor Motion Controller
Application: industrial automation control
Model: Does not apply
Case Size: 99.7 x 72 x 17mm / 3.93 x 2.83 x 0.67in
Motor Pulse Frequency: 85K HZ